FLS electromagnetic flowmeter Type 3110M for electrically conductive liquids.
Supply power and output: 24 VDC +20%, Output: passive current output, 4-20mA, max load: 500 ohms.
Reproducibility: 1% of measured value.
Errors Limits: v> 1m/s +or- 2% of measured value.
Liquid Products: largely homogeneous liquids, pastes and slurries, also w/ solid content, Electrical conductivity: >=20 uS/cm.
Protection category: IP66, equivalent to NEMA4, and 4X.
Installation in pipeline: >= DN50, Inlet/Outlet run: 10x DN/5xDN, depend on flow profile.
Electromagnetic compatibility (EMC): to EN 50081-1, EN 50082-2.
Materials**:- Sensor CrNi-stainless steel 1.4435 (SS 316 L-AISI) w/ ceramic insulation and viton gasket. Electrode: Platinium. Housing: Diecast aluminum w/ epoxy finish. Cable entry: nickel-plated brass. Gaskets: connection; sensor body FPM (Viton), Housing cover; buna N.
Ambient temperature: up to 60 C.
** Operating Pressure: <= 25 bar
** Process temperature: <= 150 C.