I can perform preventive, corrective and diagnostic maintenance.Have ability to read and understand engineering drawings such as Schematic logic, One line, Power, Wiring, Block, Cable run layout, Plc Ladder logic, Flow chart, and P& I’Ds diagrams.
Professional Experience
INDUSTRIAL SKILLS
To performed shift duty as an electrical shift technician at power generation handling main sub-station, also performed rack-in & rack-out of Air, Sf6, Oil, Vacuum circuit breakers & Contactors of 7.2/11kv & 380 volts. Also performed maintenance & troubleshooting of MS, MCCM, PCC, MCC, Motor cubicles, panels & bus bars.
GENERAL SHIFT EXPERIENCE
SF6, Vacuum, Air & Oil filled Switchgear of 7.2 /11 kv:
Preventive maintenance of Circuit breakers, Inspection, assembling, disassembling of Circuit breakers, Isolators, Earth isolators, CT’s & PT’s.
Lo voltage Metal clad Switchgear:
Circuit breakers, Contactors, troubleshooting & testing of Molded case circuit breakers & contactors.
Transformers Rated Up to 2500 KVA, 7.2/11kv:
Preventive maintenance of transformers, Change the bushings & Gaskets of transformer, Oil testing, Oil treatment, Inspection, Installation, Power cable termination & protection.
Generators Up to 1.8 MW & Emergency Generators Up to 2.1 MW:
Familiar with inspection & testing of Excitors, Automatic voltage regulators (A.V.R.) & Generator protections.
LV Motors Up to 150 KW & 380 Volts:
Overhauling, Meggering & Bearing replacement
MV Motors Up to 2.1 MW & 6.3 kv:
Meggering & Overhauling.
Protective Relays:
Familiar with operation & testing of Generators, Transformers & motors (Digital,Static, Micro processor based & Electromagnetic (compact unit type) relays are,MICOM ( P 343 ), RMS( 7000 ), MP3, MP5, MP6, 25, 27, 32 , 40, 46, 48,49, 50, 51, 51N, 51V, 51LR, 59, 64, 66, 79, 81, 83, 86, 94 and 99.
Rectifiers & U.P.S :
Preventive maintenance & troubleshooting of 80 KVA made by SICE Italy.
Batteries Maintenance:
Preventive maintenance of Ni-Cad, Lead acid & lead calcium batteries.
Variable Speed Drives:
Maintenance of VSD’s of Allen Bradley.
Batteries charger & Rectifiers:
Maintenance, Trouble shooting & repair of Rectifiers and Batteries charger.
Over head Cranes:
Maintenance & trouble shooting of Over head Cranes.1
Elevators:
Maintenance & trouble shooting of Lifts, Load checking, adjustment of Limit switches & Proximity Switches.
Use of Test Equipments:
Oil dielectric strength tester, Dehydration plant, Milliamps relay testers, High voltage tester, BICC cable fault Locater, Oscilloscope, Lux meter, Digital Earth tester, Primary & Secondary injection sets, Phase sequence meters.