maintenance technician(electrical)
This is a candidate registered on Gulfoilandgas.com. To contact this candidate you need to purchase a subscription.
Education: 2
Experience: 12 years
Relocation: Yes - Internationally
Career Objective
to obtain a good caliber of electrical position where i can apply my previous experience and technical versatility to improve the companies growth.
Professional Experience
Experience:
Presently working with Qatar Petrochemical Company (QAPCO) as an Electrical Technician for Ethylene, LDPE and Utility maintenance job, through M/S Specialized Oil Services W.L.L since December 2005.
Involving Preventive & Breakdown maintenance and trouble shooting of various field associated Equipment and machineries in Ethylene, LDPE and Utility plant.
Relay testing: Overload, Earth fault etc
Calibration of Relay such as sepam15, sepam2000 etc...
Maintenance & Testing of HT & LT motors up to 16MW.
Knowledge of analyzing, evaluating, diagnosing, and resolving equipment and process related problems.
Maintenance &Testing of Circuit breakers/Cubicles
Maintenance of Ship loader/Jetty system
I am authorized to isolate and deisolate 6.6 kv and 3.3kv circuit breakers.
Worked with M/s Almeer Technical Services from Feb 2002 to Aug 2005 as Sr. Electrical technician at KNPC Mina Al-Ahmadi Refinery in Kuwait
Maintenance & Testing of HT Transformers up to 32 MVA
Testing of Bucholz relay, Overload, Earth fault etc
Maintenance & Testing of VCB
Conditioning monitoring of HT < motors ,Transformers Desalter, UPS etc
Maintenance & Testing of S/R machines
January 1996 to January 2002 worked as Electrical Supervisor (through Joy Thomas Engg. Pvt.Ltd) with M/s Reliance Petroleum Ltd at Jamnagar in India.
Maintenance & Testing of HT< motors 11KV,6.6KV,3.3KV
Maintenance& Testing of Switchgears of 33KV,11kv,6.6kv,3.3kv substation
Actively Involved shutdown maintenance which includes, servicing/testing of switch gears,allrelays,busbar etc
Maintenance and repair of transformers and switch gears up to 33kv
Trouble shooting of motors , transformers and UPS
Run test of standby generators up to 11kv
UPS, Battery charger & battery bank maintenance
Operation and Maintenance of substation up to 33 Kv.
Experience in heat treatment job such as stress reliving, hydrogen back out.
Overall exposure to safety standards of Refinery and Petrochemicals
Eductation
Education Summary:
Technical Higher Secondary Completed (THS-Technical high school leaving certificate)
Diploma in Electrical Engineering (3 years) -
Training:
H2S Training .attended
Confined Space Entry attendant course (certificate holder)
Fire fighting course (from reliance petroleum limited)
Safe isolation and deisolation authorization.
I have experience in hazardous area such as zone 0,zone 1,and zone 2 and have thorough knowledge about the equipments and machinery which to be used in hazardous area.(such as EExd,EEx,EExn like that..)
Also I have an authorization for safe isolation and deisolation of motor and trans formers up to 33 kv and 11 kv.
I got good training in electric shock first aid like CPR from Qatar petrochemicals.
Also I have PTW for electrical job.
Certification
H2S Training .attended
Confined Space Entry attendant course (certificate holder)
Fire fighting course (from reliance petroleum limited)
Safe isolation and deisolation authorization
also i have safe isolatio and deisolation authorisation switch gears and circuit breakers upto 11 kv.