electrical protection engineer
This is a candidate registered on Gulfoilandgas.com. To contact this candidate you need to purchase a subscription.
Education: 5
Experience: 7 years
Relocation: Yes - Internationally
Career Objective
EXPERIENCES
PLACE OF WORK :-
From 21th NOV 2001 till now working in Egyptian Electricity Holding Company ( EEHC ) El kurimat ( 2x 650 MW Thermal Power Plant And 500 / 220 / 11 KV Substation as a protection Engineer.
Professional Experience
EXPERIENCE PERIOD :-
Approximately six years experience in protection relays (numerical – static – electromagnetic), event Recorder, fault recorder, fault locator and metering.
Able to read and write protection scheme and drawing.
Write reports and prepare comments, testing and supervision of all relays in 500 / 220 / 11 KV system
Eductation
Graduated from Engineering Faculty ,Helwan University , Electrical Machine & Power Department, 1999
Grade: Good
Project: Very Good
Current job: - protection engineer
Diploma at protection of electric systems in Cairo University
Certification
Onshore training:
from Jul 1997-Sep 1997 training at Cairo for electricity distribution company.
GIS SWITGEARS course at In cairo south training center from 29th Nov 2003 to 17thDec 2003.
Have gone through a course at infra-red thermograph for 3 days
POWER SYSTEM OPERATION course at national training center - Cairo south from 29/05/2004 to 10/06/2004
Total fault gas analyzer (T.F.G.A) course at national training center -Cairo south In Cairo south training center from 25th Dec 2004 to 29th Dec 2004.
P1 PROTECTION INSTRUMENT CT&VT course In Cairo south training center from 29th JAN 2004 to 16th FEB 2005.
G.E Generation Specialist From 13 -23 JAN 2007
On shore Training for maintenance of Excitation system EX2000 .
Offshore training:
1-training on SIPROTEC numerical protection relays in
GERMANY by SIEMENS from 6/8/2006 to 13/8/2006.
Additional Information
RESPONSIBILITY
Responsible on Testing and Calibration of the following : -
1- protection of 627 M.W Generator and step-up Transformer 23/500 KV
for generator protection , differential ,over excitation , loss of
excitation ,negative phase sequence, over current ,reverse power, distance, out of step, over voltage, voltage balance, rotor earth fault and phase over current restricted earth fault protection of GE relays.
2- protection of 500/220/11 KV Power Transformer and start upTransformer 220 / 6.3 KV.
Differential, over flux, directional over current, restricted
earth fault, residual voltage and earth fault of GEC and ABB.
3- Protection of Transmission Lines 500 and 220 KV .
Distance, directional earth fault and under voltage of ABB and GEC and BBC relays.
4- protection of Bus Bars 500 and 220 KV . differential and breaker fail of GEC relays.
5- protection of medium Voltage Switch Gear 6.3 and 11 KV . feeder protection SPAJ140c of ABB relays. motor protection SPAM150c of ABB relays
6- Protection of low Voltage Equipments (Power Centers) .
7- Calibration of ( Voltage , Current , MW, MVAR , MWH , Power Factor ,Frequency ) Transducers of GE.
8- Testing of Fault Recorders and Fault Locators of HATAWAY and ABB.
9- Make Fault Analysis
10 -ABLE TO Use XS92A, SVERKER 650 AND MANTA 1710-1720 TESTER
PERSONAL SKILLS
Microcontroller 89c52 series programming using assembly language and the interfacing with LCDs , A/D converters , matrix and coded keyboards,