Career Objective
Preventive, corrective and diagnostic maintenance, repairing, troubleshooting, calibration etc. includes revamping and refurbishment, instrument location layout, alarms, trips and loops checking, commissioning, function and logic test etc.
Professional Experience
Involved in the precommissioning, commissioning and start up maintenance of refinery plant. Carrying out instrument maintenance independently, involved in routine plant maintenance, preventive maintenance and shut down maintenance and attended shift duties and call out. Jobs includes Erection, Commissioning, Revamping, Loop Checking, calibration and servicing of all type of pneumatic and electronic field and Panel Instruments, Break down and MRTA/GRTA Shutdown maintenance in Refinery and Continuous Petrochemical Industries, Fault finding and Trouble Shooting in Process Control Loops, Logic Sequences, Interlock system. Involved in Start up and Shutdown jobs.
Eductation
S/N Examination Board / University Passing Year Division
01 S.S.C G.S.E.B Gandhiagar March-1995 2nd class
02 I.T.I Instrument I.T.I Sanand July-1997 Distinction
Certification
„X Familiar with scandura S-800, B-20 IS Calibrator and unomata Druck Company loop calibrator.
„X Undergone training of M/S Dott.ing.scandura calibration & instrument India pvt Ltd in Reliance industries ltd Jamnagar.
„X Undergone training of confined space entrant authorization in Kuwait national petroleum company mina al-ahmadi refinery (K.N.P.C)
„X Aware of fire and safety rules and regulation for refinery and knowledge of hazards area equipment.
„X Undergone training on Rockwell automation for control logix hardware RS link, RS network and RS logix 5000 programming software in Kuwait national petroleum company mina al-ahmadi refinery (K.N.P.C)
„X I was awarded by Reliance industries ltd. Jamnagar ¡V Gujarat for reporting near miss incident.
Additional Information
Field-Experience:
„« Maintenance and calibration of leveltrol (Fisher,Megnetrol,Masoneilan)
„« Maintenance and calibration of varies type of flow meter like DP type flow meter, wedge flow meter, vortex flow meter (Foxboro,Abb,Rosemount)
„« Maintenance and servicing of solenoid valve (Asco,Falcon,Herion)
„« Calibration of various type T/C and RTD and analog multiplexer transmitter for temperature measurement (BHEL,Thermometric corp.MTL-831B)
„« Maintenance and calibration of gauges like pressure, temperature and level (Budenburg,Wika,Klinger,Aschroft,Megnetrol)
„« Various type of switches like level,pressure,temperature (Megnetrol,E&H,Switzer,Ashcroft,Hnl ltd,Delta control and United electric ltd.)
„« Maintenance and calibration of control valve and on off valves (Fisher smart series,Keystone,Masoneilan)
„« Maintenance and overhauling of motor operated valve (Rotorq IQ range)
„« Maintenance and calibration of following analyzers
„X Charge heater flue gas stack O2 analyzers (Ametek-2000 Series,Rosemount-Oxymeter4000)
„X Hydrogen purity analyzers (Rosemount CAT-7)
„X PH analyzers caustic and oily water service (Rosemount-5081/2081)
„X Conductivity analyzers in LP condensate (Rosemount-2081 CT)
„X H/C,H2,H2S gas detector (General Monitor,Crowcon,Ultima gas monitor)