Power System Protection, Control and Metering Engineer.
This is a candidate registered on Gulfoilandgas.com. To contact this candidate you need to purchase a subscription.
Education: 2
Experience: 8 years
Relocation: Yes - Internationally
Career Objective
Provide Protection For Power system HV Equipment, Installation of HV Equipment,
Maintenance of HV Equipment
Professional Experience
EXPERIENCE
1) I have power system planning experience having worked with SYSTEM PLANNING DEPARTMENT (NATIONAL CONTROL CENTRE) OF PHCN for 5-years (1997 – 2002)
2) I have worked in PC&M (Protection Control & Metering) Department at various locations within Nigeria e.g Sapele Power Station Delta State 2003 – 2004, Akure Business Unit 2004 – 2005) & Osogbo Works Centre 2005 – to date)
3) I also have Experience in Financial Accounting as I started work as An Accounting Clerical Officer Sept 1992 – July 1997
4) I am competent and versatile on computer applications, assembly and appericiation on packages like Microsoft Office Professional, Microsoft Office Excel, Microsoft Office Word, Microsoft Office Publisher, Microsoft power Point and AutoCAD.
E PROFESSIONAL ACHEIVEMENTS
1) I was part of the team of Engineers that Installed a 75MX 330kV Power System Reactor At Osogbo Works Centre in 2004.
2) I was involved in the installation of 6 Nos DIGITAL / NUMERIC Relays on the 330kV circuits in Osogbo Works Centre 2005 – 2006
3) I was part of the team that installed 3Nos 330kV Current Transformers on Jebba 3 Circuit at Osogbo in 2007
4) I was involved in installation of A digital Relay to replace a faulty one on 60MVA 132/33kV Transformer at Akure kV Substation.
5) I regularly carry out preventive maintenance on the underlisted equipment as required by my office and job dictates as at present:
1 Maintenance of 330kV, 132kV & 33kV circuits protection relays
2 Maintenance of 330/132/33kV power transformers and 75Mx Reactor in Osogbo Works Centre of PHCN
3 Maintenance of 132/33kV power transformers within and outside Osogbo Substations.
4 Maintenance of High voltage circuit breakers Gas CB, Oil CB, Vacuum CB Air Blast CB etc.
5 Design of Protection, Control & Metering schemes for 330kV, 132kV & 33kV circuits.
6 Design of Protection, Control & Metering schemes for 330/132/33kV Power transformers,
7 Design of Protection, Control & Metering schemes for 132/33kV Power transformers.
8 Design and maintenance of Alarms and Annunciation Schemes for the above specified protection and control schemes. Technical reports are being written and forwarded to PHCN corporate HQs reqularly of which I am a chief participant.
Eductation
ACADEMIC QUALIFICATIONS/INSTITUTIONS WITH DATES(Starting with most recent)
S/No INSTITUTION QUALIFICATION & DATE
1 Federal University of Technology Akure, Ondo State Post graduate Diploma (inview)
2 Federal Polytechnic Ado-Ekiti
Ekiti State HND (lower Credit)
Nov. 2000
3 Federal Polytechnic Ado-Ekiti
Ekiti State ND (Lower Credit)
August, 1997
4 Senior School Certificate GCE WASC 1995 & 2006
Certification
PROFESSIONAL TRAININGS
1) 2-Years Pupilage training for Engineers and Technologists by Power Holding Company Of Nigeria Coordinated In-Plant And On The Job Training Department,Ijora Lagos (March 2003 –May 2005)
2) Relaying Protection Course P1 (2-Weeks Traning) organized by PHCN Professonal Skill Training Centre Kainji. April 2006
3) Engineering Safety Rules And Management Course: organized by In-Plant And On The job Training Department Ijora Lagos OCTOBER 2004 (2- Weeks duration)
4) Transformer Testing, Installation And Commissioning Workshop: Organized by PHCN Professonal Skill Training Centre Kainji OCTOBER 2007
NB
The professional course listed above are specialized training for Engineers and Technologist in PHCN especially Protection Control And Metering Engineers where I work to date.
Additional Information
EXPERIENCE
1) I have power system planning experience having worked with SYSTEM PLANNING DEPARTMENT (NATIONAL CONTROL CENTRE) OF PHCN for 5-years (1997 – 2002)
2) I have worked in PC&M (Protection Control & Metering) Department at various locations within Nigeria e.g Sapele Power Station Delta State 2003 – 2004, Akure Business Unit 2004 – 2005) & Osogbo Works Centre 2005 – to date)
3) I also have Experience in Financial Accounting as I started work as An Accounting Clerical Officer Sept 1992 – July 1997
4) I am competent and versatile on computer applications, assembly and appericiation on packages like Microsoft Office Professional, Microsoft Office Excel, Microsoft Office Word, Microsoft Office Publisher, Microsoft power Point and AutoCAD.
Hot Categories
Chemicals
Batteries