API 510 Inspector
This is a candidate registered on Gulfoilandgas.com. To contact this candidate you need to purchase a subscription.
Education: 4
Experience: 5 years
Relocation: Yes - Domestically
Career Objective
to provide good service and gain/improve knowledge and experience.
Professional Experience
Over 5 years professional inspection experience in the petroleum refining, petroleum gas, chemical process and electrical power generation industries. Extensive experience performing API 510 inspections on pressure vessels, boiler, furnace, reactor, tank, piping, welding and structural, including data reports, re-rates, hydrostatic test, pneumatic test, PQR's, WPS's, welder qualification, NDE (ultrasonic, magnetic particle, dye penetrant, holiday testing, hardness testing, vacuum box testing, and etc), fabrication, installation and repairs as per relevant code and standard (ASME, API, AWS or PTS).
Other inspection experience includes vendor surveillance, plant corrosion survey, RBI inspections, smallbore inspection program and etc which along with being computer literate- report writing, report reviewing and data input. Also, familiar with plant shutdown, preparation/planner plant turnaround and plant maintenance. Involved in repair activity with approved procedure.
Eductation
Academic : Degree in Mechanical Engineering
KUiTTHO (now known as UTHM)
-year 1998 until 2003-
Certification
Technical : Authorized API 510 Pressure Vessel Inspector
(Cert No. 28683)
-year 2006-
PCN Level II Welding Inspector
(Cert No. 211851)
-year 2004-
ASNT Level II MT/PT/UT
-year 2004-
Additional Information
Local (Malaysian Plant):
Petronas Penapisan (Melaka) Sdn. Bhd. (PPMSB), Petronas Penapisan (Terengganu) Sdn. Bhd. (PPTSB), Petronas Fertilizer (Kedah) Sdn. Bhd. (PFKSB), MTBE Sdn. Bhd., PDH Sdn. Bhd., BASF Sdn. Bhd., Toray Sdn. Bhd., Vinyl Chloride Malaysia Sdn. Bhd. (VCMSB), Optimal Chemical Sdn. Bhd., Ethelyne Sdn. Bhd., MCOT Sdn. Bhd., ESSO Malaysia Berhad Port Dickson Refinary, TNB Janamanjung Sdn. Bhd. and Malaysia LNG Sdn. Bhd. (MLNG).
International Plant:
Bharat Petroleum Corporation Limited, Mumbai India.
Date : 22 April 2009 – 10 May 2009
Company : S.E.M INSPECTION SDN. BHD.
Seremban, Negeri Sembilan.
Position : Authorized Static Equipment Inspector (API 510)
Scope work : Seconded to Malaysia LNG Sdn. Bhd. as an Static Equipment
Inspector to perform visual inspection during Module 8
Shutdown 2009.
Date : 04 March 2009 – 02 April 2009
Company : ESP (ASIA) PVT.LTD.
CBD Belapur, Mumbai, India.
Position : Authorized Static Equipment Inspector (API 510)
Scope work : Seconded to Bharat Petroleum Corporation Limited, Mumbai
India as an inspector to perform visual inspection during RMP Plant Shutdown 2009.