an application for the post of electrical technician
This is a candidate registered on Gulfoilandgas.com. To contact this candidate you need to purchase a subscription.
Education: 2
Experience: 12 years
Relocation: Yes - Internationally
Career Objective
With reference to your advertisement, my candidature for the position of Electrical technician I am working in RASGAS LNG plant . I have 12 years of good experience in executing maintenance and trouble shooting of all power plant equipments
Professional Experience
WORK DETAILS:
Presentely working with Ras Gas LNG Company in Under twt maintenance of there
Train 1&2 ,offsite, and akg section as a lead Electrical Technician
RAS GAS ONSHORE having TRAINS 1 & 2 together capable of producing 6.6 MTA
of LNG
• ELICS (ELECTRICAL INTEGRATED CONTROL SYSTEM) Generator and switchgear monitoring and control system. (SCADA)
• GE Frame 6 & 7 gas turbine generator 41 MW MARK V & VI controls 10 MW capacity Emergency DG Set CATERPILLAR
• Gas insulated Switchgear (GIS) 220 KV (FUJI) 33KV (SIEMENS, GERMENY) 6.6 KV Siemens switchboards / Vacuum Circuit Breaker, ACB, 415 V Air Circuit Breaker (HOLLECH), Reyrolle-Belmos (Scottland) 11 KV, 3.3 KV and 415 V switchboards, 11 KV & 3.3 KV OCB REYROLL BELMOS.
• Microprocessor based – 415 volts (Hollech) switchboards having Clink system (CAPITOL-40) authorized to do SCU / LCU
• 5 Rectifier unit each rated 103 KA 1650 V DC (ABB)
• 11 KV / 33 KV 33 KV / 6.6 KV, 415V / 230V, 11KV / 3.3 11KV / 415V Power, Distribution, Regulating and Rectifire Transformers (M/s. PAUWELL, ABB)
• 9.5 MW to 1KW explosion proofs motor MOV, Fin fan, loading, fire pump motors and VFD motors. (BROOK HANSEN / GEC ALSTHOM / ABB / SIEMENS / FUJI etc).
• High resistance grounding system, Plant earthing & Bonding, earthing transformer.
• Cable laying, glanding, termination, and cable fault finding of HV & LV cables.
• Microprocessor based UPS / Battery chargers,(GUTOR, SHAFT, CHLORIDE) and lead acid, alkaline and maintenance free battery cells
• Assistance to Relay testing activity & coordination, Microprocessor Based Protective Relay MULTILIN (GE) SR- 750,745,469,489, MM2, Universal Relay F60, M60, F90, DGP, AREVA family, MICOM family And Digital Generator Protection (DGP) Relay. Also worked with electromegnetic disc type overcurrent, under current, earth fault and stalling relay.
• Electric heat treasing system, heaters, cathodic protection transformer, fiber-optic level guages, spark plug of incinerators & turbines, plant lightings,
• Thermography Test and collecting vibration monitoring data
• Utilised maintenance management system SAP, CMMS system.
Eductation
ELECTRICAL AUTHORISATION & TRAINING:
Electrical competency Organisation & Institute
Authorisation Level
Assessment
Certificate of Authorisation
Ras Gas LNG Company Ltd, Ras Laffan, QATAR
Carry out 6.6 KV / 415 V Isolation / Deisolation,Lock out / Tagout, test, Apply / Remove Circuit Main Earth, troubleshooting and maintenance of Electrical Switchgear equipments and system. Practical and Theoretical
Certificate of Competency for Electrical Supervisor I. M. & E. Department, Ahmedabad, Government of Gujarat, India. License For Electrical Supervisor Granted
MCC,PCC Training Course North Atlanta college DOHA, qatar Fundamentals of Conrolsystem, Interpreting and maintaining Basic instruction, maintenance and trouble shooting and programming for panelview plus Training courses Practical and Theoretical