Reference | N.F 4501/2010 |
Date | 10/19/2010 |
Location | Middle East |
Scope | 1- Supply of # 4 electronic flow meters to measure the consumption as the following specifications: Product: (HN & LN) Pipe size: 1.5" vertical installation Flow direction towards up F.R.R.: (0.1 to 1.5) m³/hr Op.Temp: (30 to 85) Cº Op. pressure: (9 – 10) bar Differential pressure: 0.5 bar Sp. Gr.: (0.65 to 0.75) Used for units (1, 2, 3) Fueling (liquid phase) to the furnaces with strainer and air release. 2- Supply of # 4 electronic flow meters to measure the consumption as the following specifications: Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2s) Pipe size: 4" horizontal installation F.R.R.: (100 to 500) Nm³/hr Op.Temp: (30 to 65) Cº Op. pressure: (0.1 to 2.5) bar Differential pressure: 0.05 bar Density: 3.4 Kg/m³ Used for units (1, 2, 3) Fuel (gas phase) to the flair 3- Supply of # 4 electronic flow meters to measure the consumption as the following specifications: Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2S) Pipe size: 4" horizontal installation F.R.R.: (30 to 350) Nm³/hr Op.Temp: (30 to 65) Cº Op. pressure: (0.1 to 2.5) bar Differential pressure: 0.05 bar Density: 3.4 Kg/m³ Used for units (1, 2, 3) Fuel (gas phase) to the furnaces These flow meters should be blind head type (equipped with a separate remote Display) mounted on the wall 4- Supply of # 3 electronic flow meters to measure the consumption as the following specifications: Product: Gas Oil Pipe size: 1.5 "horizontal installation F.R.R.: (2 to 20) m³/hr Op.Temp: (10 to 65) Cº Op. pressure: (2 to 3) bar Differential pressure: 0.3 bar For units (1, 3) Fuel (liquid phase to the Boiler & Generator. Water & Sediment V%: 0.05 ASH Max% 0.01 weight These flow meters should be blind head type (equipped with a separate display) mounted on the wall (remote) with strainer and air release 5- Supply of # 1 electronic flow meters to measure the consumption as the following specifications: Product: Gas Oil Pipe size: 1.5" horizontal installation F.R.R.: (1 to 10) m³/hr Op.Temp: (10 to 65) Cº Water & Sediment V%: 0.05 ASH Max% 0.01 weight Op. pressure: (2 to 3) bar Differential pressure: 0.3 bar For unit (2) Fuel (liquid phase) to the Boiler These flow meters should be blind head type (equipped with a separate remote display) mounted on the wall with strainer and air release 6- Supply of # 2 electronic flow meters to measure the consumption as the following specifications: Product: Gas Oil F.R.R.: (1 to 10) m³/hr Op.Temp: (10 to 65) Cº Water & Sediment V%: 0.05 ASH Max% 0.01 weight p. Pressure: (2 to 3) bar Differential pressure: 0.3 bar For unit (2) Fuel (liquid) to the Generator with strainer and air release |
Bid Bond | 1% of submitted prices |
Documents Price | ID 100,000 |