Reference | 58.11.4108 |
Date | 9/29/2011 |
Location | Middle East |
Scope | Supply of #4 single meter run gas orifice metering skids for gas to flare measuring with defferent header size as shown bellow: 1- Two metering skids (low and high pressure flare) for ammara deg.station with header size 8" 2- Two metering skids (low and high pressure flare) for noor deg. station with header size 10". Each meter run to be supplied on structural skid and should include as minimum: - -Dual chamber orifice fitting with suitable plates to give range overlap. -Up stream flow conditioners - Differential pressure flow transmitter and 3- valve manifold. - Pressure transmitter and bleeding gauge valve. - Temperature transmitter and thermo well. - Field mounted flow computer - Appropriate drain / purge valve. Process data Fluid: natural gas. Flow rate: min 2.5 mmscf/d -max 20 mmscf/d. Normal flow rate: (2.5 -10) mmscf/d Meter type: orifice plate Operating press. : 2psig- 10psig for low-pressure flare 10 psig - 80 psig for high-pressure flare Operating temp: (0°c) - (55°c) |
Bid Bond | 1% of the bid price |
Bond Validity | 120 days |