Reference | N.F 4501/2011 |
Date | 12/30/2010 |
Location | Middle East |
Scope | It is required to supply electronic flow meters to measure the consumption fuel (Gases & Liquids) by boilers, furnaces, generators and flairs. It must be done by Ex-d flow meters offered the Net and thermally compensated volumes to (15, 20) Cº and a pressure of 1.01325 bar. The total quantity are 18 (eighteen) Flow meters. # 4 flow meters with the following Specification: Product: (HN & LN) Pipe size: 1.5" vertical installation Flow direction towards up Flow rate range(F.R.R.): (0.1 to 1.5) m³/hr Op.Temp: (30 to 85) Cº Op. pressure: (9 – 10) bar Differential pressure: 0.5 bar Sp. Gr.: (0.65 to 0.75) Used for units (1, 2, 3) Fueling (liquid phase) to the furnaces With strainer and air release # 4 flow meters with the following Specification: Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2s) Pipe size: 4" horizontal installation F.R.R.: (100 to 500) Nm³/hr Op.Temp : ( 30 to 65 ) Cº Op. pressure: (0.1 to 2.5) bar Differential pressure: 0.05 bar Density: 3.4 Kg/m³ Used for units ( 1 , 2 , 3 ) Fuel ( gas phase ) to the flair # 4 flow meters with the following Specification: Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2S) Pipe size: 4" horizontal installation F.R.R.: (30 to 350) Nm³/hr Op.Temp: (30 to 65) Cº Op. pressure: (0.1 to 2.5) bar Differential pressure: 0.05 bar Density: 3.4 Kg/m³ Used for units (1, 2, 3) Fuel (gas phase) to the furnaces These flow meters should be blind head type (equipped with a separate remote display) mounted on the wall. # 3 flow meters with the following Specification: Product: Gas Oil Pipe size: 1.5 "horizontal installation F.R.R.: (2 to 20) m³/hr Op.Temp: (10 to 65) Cº Op. pressure: (2 to 3) bar Differential pressure: 0.3 bar For units (1, 3) Fuel (liquid phase) to the Boiler & Generator. Water & Sediment V%: 0.05 ASH Max% 0.01 weight These flow meters should be blind head type (equipped with a separate display) mounted on The wall (remote) With strainer and air release # 1 flow meters with the following Specification: Product: Gas Oil Pipe size: 1.5" horizontal installation F.R.R.: (1 to 10) m³/hr Op.Temp: (10 to 65) Cº Water & Sediment V%: 0.05 ASH Max% 0.01 weight Op. pressure: (2 to 3) bar Differential pressure: 0.3 bar For unit (2) Fuel (liquid phase) to the Boiler These flow meters should be blind head type (equipped with a separate remote display) mounted on the wall. With strainer and air release # 2 flow meters with the following Specification: Product: Gas Oil F.R.R.: (1 to 10) m³/hr Op.Tem: (10 to 65) Cº Water & Sediment V%: 0.05 ASH Max% 0.01 weight P. pressure: (2 to 3) bar Differential pressure: 0.3 bar For unit (2) Fuel (liquid) to the Generator With strainer and air release |
Bid Bond | 1% from submitted prices |
Documents Price | ID 100000 |