Reference | 97101022 |
Date | 12/25/2010 |
Location | Middle East |
Scope | #2 Atomic Absorption Spectrometers (AA 7000). Double beam Flame/Furnace (Auto Sampler and Furnace included) with analyzing organic solvents by flame analysis option and Automatic Adjustment of Flame height / Furnace height with Analog output Cable. Specification: - Wavelength range 185.0 to 900.0 nm, - Bandwidth 0.2, 0.7, 1.3, 2.0L nm (4-step automatic switching, - Photomultiplier tube Detector - Optical double-beam - 6-lamp turret, 2 lamps simultaneously, EMISSION, NON-BGC, BGC-D2, BGC-SR lamp mode 5.0, 2.5, 1.25, 0.625 Abs. /V , Aberration-corrected Czerny-Turner mounting Monochromator. With accessories as below: # 2 Graphite Furnace Atomizer Graphite Furnace Atomizer and three type of tube (High Density , Pyro-Coated and Platform tube ) Specification: Heating temperature range Ambient to 3,000 °C, Power requirements 200, 220, 230, or 240 VAC ±5%, 6000 VA, 50/60 Hz #2 Autosampler To Advanced Sample Pretreatment Functions and Compatible with AAS System requirements Specification: With RS-232C communication control from AA unit Maximum reagent / sample positions Reagents: 8 positions Samples: 60 positions (random access available with reagents or samples) Rinse water bottle 2 L Power requirements 220, or 230 VAC, 50 VA, 50/60 Hz #2 Hydride Vapor Generators Need to measure As, Se, Ge, Sn, Sb, Te, Bi, or Hg. Specification: According to System requirement #4 Flame Micro Sampling At least 1ml (1000µL ) volume of a liquid sample is required for the continuous intake of sample during normal flame analysis. With micro sampling Specification: According to System requirement #4 Nitrous/Acetylene Burner High Temp Burner Extremely corrosion-resistant to determination of Elements Which form refractory oxides like (Al,B,Ba,Be,La,Mo,Re,Si,Sn,Ti,V,W,Zr.) Which Present in Some types of catalyst. Specification: Made of pure titanium. Air-cooled. 5 cm slot of N20-C2H2 flame and Can also be used for Air-C2H2 flame #4 Air /Acetylene Burner Extremely corrosion-resistant 10 cm slot of Air-C2H2 flame to determination of Elements Which not form refractory oxides Specification: Made of pure titanium According to System requirement # 2 Water Chiller It Requires to Cooling furnace and compatible with system (graphite furnace) Specification: Power required 220 – 230 And According to System requirement # 2 Air Regulator, Acetylene Regulator, Nitrous Regulator, Argon Regulator to control Gas Flow Specification: All part Conformable to Its Purpose specifications #2 Air Compressor and Auto Tank Drain for 5 gallon tank with pressure regulator and gauge. Includes 5 micrometer filter and moisture filter and dust filter and With All Accessories Specification: Power required 220 – 230 V and According to System requirement #4 Hose ASSY For air, C2H2 and N2O gases supply Specification: R-Nylons Tube Type or Polyethylene type And the Size According to System requirement # 10 Hose clamp (16 mm) According to System requirement # 4 Cleaning Kit Included Wire nebulizer cleaning and Blade Burner Cleaning Specification: According to System requirement #10 meter Sampling tube PTFE or Silicon Tube Specification: 0.64 mm or According to System requirement #10 meter Sampling tube (for organic solvent samples) To Organic samples Specification: Resistance to organic solvent #20 meter Drain ASSY To drain samples from instrument Specification: PVC Type #2 ventilation System Blower Exhaust pipe adapter (6" exhaust pipe) Vent Hood (6" x 12" inlet) Specification: Power required 220 – 230 V Hallow cathode Lamps: two for each element Aluminum, Antimony, Arsenic, Barium, Beryllium, Bismuth, Boron, Cadmium, Calcium, Cerium, Cesium, Chromium, Cobalt, Copper, Iron, Lanthanum, Lead, Lithium, Magnesium, Manganese, Mercury, Molybdenum, Nickel, Palladium, Platinum, Potassium, Rhenium, Selenium, Silicon, Silver, Sodium, Strontium, Tin, Titanium, Tungsten, Vanadium, Zinc, Zirconium Specification: All lamps are D2/SR Back ground correction compatible Standard Solution for each Element: 2×500 ml for each Element Calibration Solutions Specification: 1000 ppm Triple check Solutions # 2 Personal Computer Full System Dell Personal computer With WizAArd Software Pre-Installed. And Compatible with apparatus requirements Specification: Operating system Microsoft Windows Vista Business / XP Professional (registered trademarks of Microsoft Corp., U.S.A.), CPU: 2.53 GHz CORE 2 DUOS, RAM: 4 GB, Monitor: XGA (1024 × 768 dots) or higher Storage device: One DVD RW drive (for installing software), H.D: 500 GB. Hard disk space for AA installation, I/O port: (com 1) serial port (for AA control) com 2) Optional serial port with at least 4 USB portPeripheral devices: keyboard, mouse. # 2 printer Colored Printer Laser Specification: Colored Printer Laser # 3 Cable Set # 2 Card (Set of 10 ) Include Instrument Electronics Cards and Boards # 2 Instruction Manual book Explain Installation the Software Features and Instrument Specification Specification: English Language # 2 Service Manual Explain Instrument Installation and maintenance Specification: English Language # 2 Standard Analytical Method Book To all Chosen Elements Specification: English Language # 2 inspection report Specification: English Language #2 Safety inspection Sheet Specification: English Language # 2 - Declaration of conformity, explanatory notes ( ISO-9001) Specification: English Language #2 Warranty label Specification: English Language # 2 Serial Number label Specification: English Language - Spare Parts Kit For Item 1 ( AAS ) and Accessories Items include ( 1,2,3,7,9 and 13 ) for two years . - Witness two Persons to 10 Days. - Guarantee shall be One Year after Operation. - Origin of apparatuses and all Its accessories should be from following Origins: 1-Japanese . 2-American . 3-United Kingdom . 4-Germany . |