Egypt Zones accountACCOUNT
Cathodic Protection Transformer Rectifiers
Transformers
Reference 66/2010/C
Date 9/9/2012
Location Middle East
Scope Quantity: 20 units
Descripition:
1- input A.C: 220-250 V. single phase. 50 HZ
2- Output D.C, 60 volt / 60 amps
3- type: outdoor plinth mounting suitable for operation in hazardous areas
For: EX, zone 2 with IP 255 degree of protection
4- Cooling: oil immersed natural convection cooled
5- ambient temperature for outdoor operation from – 10C' up to + 50C' (shade temperature).
6- Control : D.C output voltage variable from 0 up to 100% of 3 number 4 position switches ( coarse, medium, fine) giving control over the normal range.
7- Protection
A- A.C input Fuse
B- D.C output fuse
C- Rectifier fuse
D- Transient over voltage surge suppression
f- All the live components (all parts which may be result explosion) inside oil tank are always under the oil column
G- If due to oil leakage or any other reason the oil level in the tank goes down then a built – in oil level sensing device automatically trips the unit when oil column thickness above the live components becomes less than minimum 20 mm.
H- An indicator contiously indicates the temperature to the oil in side the tank if the oil temperature increase between (80-90) C' then the unit will be trip automatically.
I- all the controls and indication components and the meters outside (oil tank and will be fixed in box behind lockable front contains toughened and robust plexiglass window for viewing the meters and will be fitted in weather proof and against explosion EX, Zone 2 IP>= 55
J - Paint finish: all external surface and internal surface of the air filled chambers are protected against corrosion for long term operation in exterior expose polluted atmosphere.

8- Transformers: T1 variable auto transformer
T2 main rectifier transformer with double wound and a variable primary voltage of 0 UP to 220-250 v
9- Other features:
A- D.C voltmeter
B- D.C ammeter
C- Oil level gauge
D- Inclusive the oil quantity is required
E- Oil thermometer indicator
F- Silica- gel breather
10- Catalogue includes:
A- Circuit description and installation and operation and control of the unit
B- Circuit diagram for unit
C- Spare parts list
D -Maintenance and fault finding
11- Required Spare parts:
A.C input fuse (set)Qty:40
D.C output fuse (set)Qty:40
Rectifier fuse (set)Qty:40
D.C ammeter Qty:20
D.C voltmeter Qty:20
D.C Surge arrester Qty:20
Silica – gel breather Qty:20
Oil thermometer indicator Qty:20
A.C input on/off switch Qty:20
D.C output on/off switch Qty:20
Coarse output voltage control switch Qty:20
Medium output voltage control switch Qty:20
Fine output voltage control switch Qty:20
Main rectifier diodes- set (D1=D2, D3-D4) for each unit Qty:20
T1 variable auto transformer 1PH Qty:4
T2 main rectifier transformer (double wound)Qty:4
Oil level sensor enclosure Qty:20
Oil temperature sensor enclosure Qty:20

Bidding Information

Bid Bond Euro 1500
Transformers
Related Prooducts: Transformers Batteries Cable Trays Cables Cathodic Protection Contactors Control Panels Earthing materials Electric fittings & junction box General Lighting Panel Components Switches Transformers Umbilical Lines
Related Tenders: Accumulators and Storage batteries Batteries Cable Trays Cables Cathodic Protection Circuit Breakers Contactors Control Panels Earthing materials Electric fittings & junction box Frequency Inverter General Lighting Panel Components Starter Switches Transformers Umbilical Lines UPS

Related Articles

For Buyers
Advertise your Purchasing Requests

For Suppliers
Promote your Products
Egypt Zones
Copyright © Universal Solutions All rights reserved. - Privacy Policy.