Reference | 82-13-9020-01 |
Date | 7/10/2013 |
Location | Middle East |
Scope | Supply of 3- phase mobile test separator with automatic controls on gas pressure. Maximum Working pressure 1,440 psig @ 122°F 1,332 psig @ 250°F Process design temperature -20° to 250° F Maximum Gas Capacity 90 MMSCF/D Maximum Liquid Capacity 16,000 B/D Service conditions H2S / CO2 The separator equipped with shrinkage tester and is protected from high pressure by a rupture disk. In series with safety relief valve. Inlet oil 4-in. (3-in. union female fig. 602 ) Gas Outlet (2 Lines) Line 1: ID 6 in. with Daniels Senior Orifice fitting flange neck. Line 2: ID 3 in. with Daniels Senior Orifice fitting flange neck. Oil Outlet (2 Lines) Line 1 : ID 3 in. ( 3 in. union male fig. 602) Line 2: ID 2 in. ( 3 in. union male fig. 602) with flow meter on each tube Water Outlet 3 in.( 3 in. union male fig. 602) with flow meter Pressure sensing points Inlet , gas, oil, and water line Temperature sensing points Inlet , gas, oil, and water line Liquid sampling points Inlet , gas, oil, and water line Gas measurement equipment Daniel orifice meter 3- pen static pressure /temperature and differential pressure Barton recorder for each gas lines With (5000 chart recorder sheet) Two Set of the Orifice plate to Daniel (3) inch, (6) inch for all sizes to each one. With Operation and Maintenance Instruction. |
Bid Bond | 1% from Submitted Prices |