Reference | SDI1439P17 |
Date | 6/13/2016 |
Location | Asia |
Scope | The company invites bids for the supply of Qty- 01 No., LT Panel for Well-14, Moran. The Details of Components of the LT Panel are as follows:- * Incomer:- - Two nos. 250 amp, 415V, FP, 36 kA fault level, MCCB with in-built electronic short circuit, overcurrent and earth-fault protection release unit and a 230 V AC shunt trip as incomer. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. - The outgoing of incomer shall terminate on 400 amp (Free air rating of bars) TPN bus bars of rectangular sections of aluminum confirming to IS 5082. Rating of neutral bar shall be 100 % of phase bus rating. PVC insulated bus bars shall be supported on SMC supports suitable for 50 kA fault level. - Brought out type Terminal links of rectangular sections of aluminum confirming to IS 5082 shall be provided at incomer side of MCCB for terminating incoming supply cable. Cable size: 1 nos. of 3.5C x 240 sq mm PVCA, stranded aluminum cable. - Three Phase, 4-wire Digital Multifunction meter, (V+A+Hz+KW+PF+KWH+Maximum demand with RS 485 port), 1A instrument protection mcbs and Six nos. metering class, Resin cast CTs. CTR-300/5, 15 VA, Class 1 of IS:2705, shall be mounted on the front door. - Supply ON and MCCB OFF/ON/TRIP Indications (Cluster LED type with low voltage glow protection) shall be provided. * Outgoings:- 1) Three nos. 100 amps, 415V, FP, 25 kA fault level, MCCB with in-built electronic short circuit, overcurrent and earth-fault protection release unit and a 230 V AC shunt trip. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. 2) Seven nos. 100 Amps (set at 63 amps), 415V, FP, 25 kA fault level, MCCB with in-built electronic short circuit, overcurrent and earth-fault protection release unit and a 230 V AC shunt trip. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. 3) Two nos. 40 amps, 415V, FP, 25 kA fault level, MCCB with in-built electronic short circuit, overcurrent and earth-fault protection release unit and a 230 V AC shunt trip. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. 4) MCCB OFF/ON/TRIP Indications (Cluster LED type with low voltage glow protection) shall be provided for all outgoing feeders. 5) Brought type Terminal links / Terminals, suitably sized shall be provided at the outgoing side of MCCBs / mcbs for terminating outgoing supply cable. |
Bid Bond | Rs 71,000.00 |
Bond Validity | 180 days |
Offer Validity | 90 days |
Documents Price | Rs 1,000.00 |