Egypt Zones accountACCOUNT
Supply of LT Panel
Panel Components
Reference SDI1868P17
Date 7/26/2016
Location Asia
Scope The company announces its need for supply 5 Nos LT panel for OIL, Moran.

Detail of Components of LT Panel for Sub-Station-A (Moran):
Three nos. 400 amp, 415V, FP, 36 kA fault level, MCCB with in-built electronic short circuit, over current and earth-fault protection release unit and a 230 V AC shunt trip as incomer. The Feeder shall be provided with an Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. The outgoing of incomer shall terminate on 600 amp (Free air rating of bars) TPN bus bars of rectangular sections of aluminum confirming to IS 5082. Rating of neutral bar shall be 100 % of phase bus rating. PVC insulated bus bars shall be supported on SMC supports suitable for 50 kA fault levels. Brought out type Terminal links of rectangular sections of aluminum confirming to IS 5082 shall be provided at incomer side of MCCB for terminating incoming supply cable. Cable size: 2 nos. of 3.5C x 240 sq mm PVCA, stranded aluminum cable. Three Phase, 4-wire Digital Multifunction meter, (V+A+Hz+KW+PF+KWH+Maximum demand with RS 485 port), 1A instrument protection mcbs and Six nos. metering class, Resin cast CTs. CTR-400/5, 15 VA, Class 1 of IS:2705, shall be mounted on the front door. Supply ON and MCCB OFF/ON/TRIP Indications (Cluster LED type with low voltage glow protection) shall be provided.

Detail of Components of LT Panel for Moc(Moran): : (Qty- 01 No.)
Two nos. 250 amp, 415V, FP, 36 kA fault level, MCCB with in-built electronic short circuit,over current and earth-fault protection release unit and a 230 V AC shunt trip as incomer. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. The outgoing of incomer shall terminate on 400 amp (Free air rating of bars) TPN bus bars of rectangular sections of aluminum confirming to IS 5082. Rating of neutral bar shall be 100 % of phase bus rating. PVC insulated bus bars shall be supported on SMC supports suitable for 50 kA fault levels. Brought out type Terminal links of rectangular sections of aluminum confirming to IS 5082 shall be provided at incomer side of MCCB for terminating incoming supply cable. Cable size: 1 nos. of 3.5C x 240 sq mm PVCA, stranded aluminum cable. Three Phase, 4-wire Digital Multifunction meter, (V+A+Hz+KW+PF+KWH+Maximum demand with RS 485 port), 1A instrument protection mcbs and Six nos. metering class, Resin cast CTs. CTR-300/5, 15 VA, Class 1 of IS:2705, shall be mounted on the front door. Supply ON and MCCB OFF/ON/TRIP Indications (Cluster LED type with low voltage glow protection) shall be provided.

LT Panel for SHALMARI GCS, (Qty- 01 No.)
Two nos. 400 amp, 415V, FP, 36 kA fault level, MCCB with in-built electronic short circuit, over current and earth-fault protection release unit with in-built display and a 230 V AC shunt trip as incomer. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. The outgoing of incomer shall terminate on 600 amp (Free air rating of bars) TPN bus bars of rectangular sections of aluminum confirming to IS 5082. Rating of neutral bar shall be 100 % of phase bus rating. PVC insulated bus bars shall be supported on SMC supports suitable for 50 kA fault level. Brought out type Terminal links of rectangular sections of aluminum confirming to IS 5082 shall be provided at incomer side of MCCB for terminating incoming supply cable. Cable size: 2 nos. of 3.5C x 240 sq mm PVCA, stranded aluminum cable. Three Phase, 4-wire Digital Multifunction meter, (V+A+Hz+KW+PF+KWH+Maximum demand with RS 485 port), 1A instrument protection mcbs and Six nos. metering class, Resin cast CTs. CTR-400/5, 15 VA, Class 1 of IS:2705, shall be mounted on the front door. Supply ON and MCCB OFF/ON/TRIP Indications (Cluster LED type with low voltage glow protection) shall be provided.

Detail of Components of LT Panel for OCS1 SHALMARI (QTY- 01 NO.)
Three nos. 400 amp, 415V, FP, 36 kA fault level, MCCB with in-built electronic short circuit, over current and earth-fault protection release unit and a 230 V AC shunt trip as incomer. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. The outgoing of incomer shall terminate on 600 amp (Free air rating of bars) TPN bus bars of rectangular sections of aluminum confirming to IS 5082. Rating of neutral bar shall be 100 % of phase bus rating. PVC insulated bus bars shall be supported on SMC supports suitable for 50 kA fault level. Brought out type Terminal links of rectangular sections of aluminum confirming to IS 5082 shall be provided at incomer side of MCCB for terminating incoming supply cable. Cable size: 2 nos. of 3.5C x 240 sq mm PVCA, stranded aluminum cable. Three Phase, 4-wire Digital Multifunction meter, (V+A+Hz+KW+PF+KWH+Maximum demand with RS 485 port), 1A instrument protection mcbs and Six nos. metering class, Resin cast CTs. CTR-400/5, 15 VA, Class 1 of IS:2705, shall be mounted on the front door. Supply ON and MCCB OFF/ON/TRIP Indications (Cluster LED type with low voltage glow protection) shall be provided.

Detail of Components of LT Panel fOR OCS2, SHALMARI (QTY- 01 NO.)
Two nos. 500 amp, 415V, FP, 36 kA fault level, MCCB with in-built electronic short circuit, over current and earth-fault protection release unit and a 230 V AC shunt trip as incomer. The Feeder shall be provided with a Earth-Leakage Relay with compatible CBCT having settings: 0.03 to 3 Amps and time settings 0.15 to 3 secs. The outgoing of incomer shall terminate on 800 amp (Free air rating of bars) TPN bus bars of rectangular sections of aluminum confirming to IS 5082. Rating of neutral bar shall be 100 % of phase bus rating. PVC insulated bus bars shall be supported on SMC supports suitable for 50 kA fault level. Brought out type Terminal links of rectangular sections of aluminum confirming to IS 5082 shall be provided at incomer side of MCCB for terminating incoming supply cable. Cable size: 2 nos. of 3.5C x 240 sq mm PVCA, stranded aluminum cable. Three Phase, 4-wire Digital Multifunction meter, (V+A+Hz+KW+PF+KWH+Maximum demand with RS 485 port), 1A instrument protection mcbs and Six nos. metering class, Resin cast CTs. CTR-500/5, 15 VA, Class 1 of IS:2705, shall be mounted on the front door. Supply ON and MCCB OFF/ON/TRIP Indications (Cluster LED type with low voltage glow protection) shall be provided.

Bidding Information

Bid Bond INR 90,000.00
Bond Validity 180 days
Offer Validity 90 days
Panel Components
Related Prooducts: Panel Components Batteries Cable Trays Cables Cathodic Protection Contactors Control Panels Earthing materials Electric fittings & junction box General Lighting Panel Components Switches Transformers Umbilical Lines
Related Tenders: Accumulators and Storage batteries Batteries Cable Trays Cables Cathodic Protection Circuit Breakers Contactors Control Panels Earthing materials Electric fittings & junction box Frequency Inverter General Lighting Panel Components Starter Switches Transformers Umbilical Lines UPS

Related Articles

For Buyers
Advertise your Purchasing Requests

For Suppliers
Promote your Products
Egypt Zones
Copyright © Universal Solutions All rights reserved. - Privacy Policy.