Reference | 3527/2020 |
Date | 6/24/2020 |
Location | Middle East |
Scope | The company announces its need for supply of Analyzer and Reading SO2. - Item 001, QTY=1 of Files and online Thermo Scientific sola II trace Isomerization sulfur analyzer explostion proof complete. - Dual online stream to analyzing and reading SO2 ratio directly. - Pulsed UV Fluorescence (PUVF), with pyrolyzer for total sulfur measurement as SO2. - Application: two stream inlet and outlet reactor (R-101) to analyzing sulfur ratio in naphtha to prevent catalyst poisoning. - Tag: Stream 1: AT-007A. Stream 2: AT-007 B. - Easy calibration with digital screen (LCD) bright (not touch). - Locally Re-calibrations available. - Fast response and stable time: at (1 minutes or less). - Accuracy (calibration and measurement): ±0.01% of full scale. - Alarm: High and low alarm. - Filter system before inlet sample. - Single vent 1/4? NPT connections, inlet and back pressure regulators, pressure gauges, bypass filter and associated hardware, all wetted parts are stainless steel. - Ambient temperature: -10 to 70 Co. the analyzer should be supplied inside housing cabinet this housing should be cooling by instrument air system. - Explosion proof class 1, group B, C & D division 1. II 2G EXd&e IIC T4 Ga IP66. - Power: 110 VAC, 50Hz. - Output: Bright digital readout 4-20mA. - Isolated analog, RS485, Modbus and Ethernet output available. - Any part is accepter to maintenance and replacement. - Spear parts for two years. Should be with one probes. - All necessary equipment Software and special tools for installation and calibration should be provided. - All necessary sulfur cylinders calibration . with cylinder regulator. - Equipment instructions and data book, operating manual and complete set of drawing (certified) (English language). - Item 002, QTY= 1 of Indicator - Indicator screen instilled in control room. - Dual scales for stream1 and stream 2. - Signal indicator showing actual sulfur reading. - Signal from analyzer to screen 4-20 mA. - Scales adjustment available. Distance from field to control room 250 meters. - Item 003, QTY= 1 of Probe as spear part same model with online sulfur analyzer probe. - Item 004, QTY=1 of Installation All activates Installation, programming, connect the analyzer with control room, testing and commissions even make the equipment ready to start going to achieve by vendor or subcontractor. - Item 005, QTY=6 of Training - Training course about maintenance, calibration, installation and programming for six instrument engineer. Training course should be in the site. |
Bid Bond | US 6,000.00 |
Bond Validity | 120 days |
Offer Validity | 120 days |
Documents Price | ID 250,000.00 |