Egypt Zones accountACCOUNT
EPC of Umbilicals, Flowlines, Risers and Installation Works for Bonga North Project (EPC 2)
Umbilical Lines
Reference CW497773
Date 5/28/2022
Location Africa
Scope The Company invites interested and reputable contractors to indicate an expression of interest and apply for the pre-qualification, for consideration to tender (with reference number CW497773) for the Engineering, Procurement and Construction of Flowlines, Risers, Umbilicals and Installation works for the Bonga North field development Project.

Scope of Work
The scope of work shall include but not limited to the design, engineering, procurement transportation, offshore installation and commissioning of the flowlines, risers and Umbilicals, transportation to site and installation of other project hardware delivered by EPC-3 (Subsea Hardware Contractor), which includes amongst others the following activities:
Installation of Flowlines (for production and Water Injection) including but not limited to tie-in to Risers, hook up to the Subsea Hardwares and Umbilicals/Controls;
Installation of Risers (for Production and Water Injection) including tie back to Bonga Main FPSO as a minimum.
Installation of the Dynamic, Static, and bundled Umbilicals including Gas Lift Riser;
Transportation, offshore installation and pre-commissioning of Flowlines, Risers and Umbilicals/Controls;
Offshore transportation, installation and pre-commissioning of Subsea Hardware for EPC-3;
Support the commissioning efforts of Flowlines, Risers, Umbilicals and Subsea Hardwares.
Subsea Facility Dimension:
12’’ X 35.8 km wet insulated production flow loop (Dual line)
14” x 18.4 km injection flowline (single water)
2 x 1 slot Gaslift Inline Tee
1 x 1 slot WI Inline Tee
2nos about 36km (dynamic + static umbilical)
1 Riser base Umbilical for Gas lift manifold
Associated umbilical termination head
Mandatory Requirements
To be eligible for this tender exercise, interested contractors are required to be pre-qualified and active in the Product Group: 4.05.04 (Pipeline Systems); 4.05.05 (Risers); 4.05.06 (Umbilicals) in NipeX Joint Qualification System (NJQS) data base. Only successfully pre-qualified suppliers in these categories who can also prove with requisite evidences, will receive Invitation to Tender (ITT).

A.) Technical Capability & HSE Management:
Provide a list (with values) of all major contracts above $300MM executed within the last 5years in the Deepwater Offshore environment of 800metres water depth and potential future major projects being considered.
Provide evidence of Dynamic and Static Steel Tube Umbilicals designed and installed at a minimum water depth of 800 meters and in operations on previous executed project not more than 5 years. Also provide evidence of bundled Gaslift umbilical Riser System installed.
Provide evidence of Subsea Flowline Systems designed and installed at a minimum water depth of 800 meters and in operations on previous executed project not more than 8 years.
Provide evidence with detailed information on in-country owned or leased fabrication yard and facilities with a quayside hard standing length of a minimum of 150m, a minimum draft of 6m water depth, and existence/availability of at least 300MT cranage at the loadout quayside.
Provide verifiable evidence (completion certificate where necessary, manhours) of participation in and execution of an engineering design for the delivery of a Deepwater Flowline and Riser System at a minimum water depth of 800 meters.
Provide evidence of project completion certificates of participation/execution of the supply of Deepwater Line Pipe, Valves and Risers.
Provide evidence of company’s geographical coverage to support activities in Nigeria, including names of affiliates in different countries either owned or through alliances with design houses/fabrication yards. Details should include resource structures, size and composition of the work force (e.g., fully resourced @In-house” alliance / partnership, sub-contracted construction, etc).
Provide project completion certificate on Umbilicals, Flowlines and Risers installation from installation vessel in water depth of equal or greater than 800m, detailing the name and type of Installation vessel, project scope not more than 5 years.
Provide evidence of HSSE Management System, Social Performance (SP) Plan and Worker Welfare Management Plan for a similar executed project in the past 5 years. Details of your HSE management system shall also include incident and injury free reports, and the company interfaces with Subcontractors HSE system.
Provide a valid quality management system in compliance with the requirements of ISO 9001 and be certified by ISO approved and registered quality assurance company. Provide valid ISO 9001 certificate.
B.) Regulatory Compliance:
Address of Registered Office in Nigeria and Name of Legal Entity;
Registration Number & Category (include CAC Form C02 & C07 and NUPRC Permit and COREAN CERTIFICATES);
Provide documentary evidence of a liaison/partnership with a Nigerian registered company where any consortium partner is not registered in NipeX;
Name and address of the Ultimate Holding Contractor (if the Respondent is a subsidiary member of a group); Respondent’s office for this work;
A valid Tax clearance for the past 3 years

Bidding Information

Umbilical Lines
Related Prooducts: Umbilical Lines Batteries Cable Trays Cables Cathodic Protection Contactors Control Panels Earthing materials Electric fittings & junction box General Lighting Panel Components Switches Transformers Umbilical Lines
Related Tenders: Accumulators and Storage batteries Batteries Cable Trays Cables Cathodic Protection Circuit Breakers Contactors Control Panels Earthing materials Electric fittings & junction box Frequency Inverter General Lighting Panel Components Starter Switches Transformers Umbilical Lines UPS

Related Articles